Why Drives Aren't Tuned
Whine, Whine, Whine. Life is full of excuses. Last week I was responsible for a drive upgrade. The day ended, the line is running and the drive is not tuned. Let me list the excuses. Installation took a long time. ·         The 3 phase cabl...

[Read the rest of this article...]

Posted in: Drives, Tuning
07
Drives tuned too slow
At the IWEB conference at Oklahoma State University in 2011, one of the feature speakers, Dr. Günther Brandenburg, presented an interesting paper about tension control for printers. In the course of his research with a major printer manufacturer, he noted the requirement for faster tension regu...

[Read the rest of this article...]

30
Simple as Possible, Accurate as Necessary
Dr. Günther Brandenburg, speaking at the IWEB conference at Oklahoma State University in 2011 spoke of making the controls as Simple as Possible, but as Accurate as Necessary. His keynote address was titled "Advanced Process Models and Control Strategies for Rotary Printing Presses". This soun...

[Read the rest of this article...]

23
Processor Power
When I started my career in drive control and automation, I tried hard to do the most with the least processor power and the least memory. I learned which data types used the least memory and executed the quickest. We all knew that no one could possibly use 64K of memory. That policy of conserving ...

[Read the rest of this article...]

Posted in: Tuning, Design
16
I Saw a Generator Flash
This week while calmly investigating drive performance on a very old drive system, I saw it happen - a massive commutator flash on the dc generator feeding a drive motor for a web handling line. No one was hurt. The Motor-Generator (M-G) system is over 50 years old-but so am I. The motors and gener...

[Read the rest of this article...]

Posted in: Safety, Maintenance
09
Torque Boost
  Often the Torque Hold function provides adequate tension during most of the index, but may not provide enough tension for a good clean cut. The knife may require a very taut web if the web is stretchy. In this case, Torque Boost is required. Torque Boost is used instead of Tension Boost, be...

[Read the rest of this article...]

27
Community Bike Shop
I spent a couple of pleasant hours in a community bike shop in my town this week. While there, I got some grease on my hands while replacing some worn parts on my bike. I got the help I needed, and it was a pleasure taking the crank apart with the proper tools. Quite different from sitting at a comp...

[Read the rest of this article...]

Posted in: Maintenance
26
Torque Hold
Many events happen during a turret winder index that make it very difficult to control tension. An old, but practical, technique for surviving an index is to put the outgoing spindle into Torque Hold mode. Torque Hold is a drive function that memorizes the torque at a particular instant, and then...

[Read the rest of this article...]

19
Tension Boost
One of the drive tools available for turret winder applications is tension boost. This function is different than torque boost. Tension boost is not always required. It may be required if the winder includes a layon roller or rider roller. The layon roller is removed for the turret index and thus t...

[Read the rest of this article...]

12
Virtual Machines
Many older drive systems rely on programming tools that will only run on older operating systems. The drive program may run only on an old DOS or Windows operating system. Newer operating systems on modern computers simply laugh when you try to install the drive program. One way of keeping these ol...

[Read the rest of this article...]

Page 1 of 10First   Previous   [1]  2  3  4  5  6  7  8  9  10  Next   Last   

Blogmaster

Clarence Klassen photo

Clarence Klassen

President. Designated Consulting Engineer with Professional Engineers Ontario (PEO). KlassENgineering was incorporated in 1999. Clarence applies 31 years in the Pulp and Paper industry to solving problems with drives for web handling. He has 10 years experience as a drives engineer with GE Canada and 10 years experience with Opcode Systems Inc., a PLC and Drives Systems Integrator. Much of Clarence's experience was gained in onsite installation of new equipment and troubleshooting of existing equipment. KlassENgineering performs Pre-Start Health and Safety Reviews as required by the Ontario Ministry of Labour.